FANUC Alarm SVGN-170 — Incompatible PRESS_MOTN format.
FANUC SVGN-170 (“Incompatible PRESS_MOTN format.”): The instruction format PRESS_MOTN[SD=,P=,SEL=(,)] cannot be used with the setting $SGSYSDG.$UGA_IDX4GB=FALSE. First check: If you want to use the instruction format PRESS_MOTN[SD=,P=,SEL=(,)] then set $SGSYSDG.$UGA_IDX4GB=TRUE.
Updated 2026-09-17 · LogrobotLM reference
Description
The instruction format PRESS_MOTN[SD=,P=,SEL=(,)] cannot be used with the setting $SGSYSDG.$UGA_IDX4GB=FALSE. GunB must use GunA data, for this instruction.
Remedy
If you want to use the instruction format PRESS_MOTN[SD=,P=,SEL=(,)] then set $SGSYSDG.$UGA_IDX4GB=TRUE. If you do not want to use the instruction format PRESS_MOTN[SD=,P=,SEL=(,)] then change the instruction to PRESS_MOTN[SD=(,),P=(,)] ( the setting of $SGSYSDG.$UGA_IDX4GB is ignored for the format PRESS_MOTN[SD=(,),P=(,)] ).