FANUC Alarm SVGN-220Set value is wrong

Description

A set value is wrong. The calculated weight has become negative.

Remedy · Remède

The interval between angle and angle at pressure calibration should be away by 70 degrees or more. Confirm the set value of the angle. The pressure or the command pressure might be wrong. Confirm the set values of the pressure and the command pressure.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.