FANUC Alarm SRVO-371 — SVON2 status abnormal

Error
Hardware
emergency stop and dual safety chains
Controllers
R-30iA / R-30iB
FANUC class
SERVO

FANUC SRVO-371 (“SVON2 status abnormal”): A chain alarm was detected with the panel board internal signal (SVON). First check: Replace the panel board. Likely part: Panel board (Operator panel board).

Updated 2026-10-22 · LogrobotLM reference

Description

A chain alarm was detected with the panel board internal signal (SVON).

Remedy

Replace the panel board.

Field diagnosis

Chain alarm on channel 2 of the internal SVON signal.

What to check

  • Same replacement sequence as SRVO-370: panel board (R-30iA) or main board (R-30iB, after backup), then amplifier, then emergency stop board.
  • Note: Rarely occurs on its own; look at the other chain codes from the same second.

Part to check / replace

FANUC SRVO-371 points to the hardware below — start here before ordering.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.

Related codes

Same hardware involved

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →