ABB Motion error codes
443 codes · Liste complète — signification et vérifications.
50001Grave erreur mouve-50021Controller hardware fault50022Too low DC-link voltage50023Erreur de Stop/Reprise50024Corner path failure50025Restart interrupted50026Close to singularity50027Joint out of range50028Jog in wrong direction50029Robot outside its limits50030Robot outside its limits50031Command not allowed50032Command not allowed50033Command not allowed50035Command not allowed50036Correct regain impossible50037MOTORS ON order ignored50041Robot in a singularity50042Could not create path50050Position outside reach50052Joint speed too high50053Too large revolution counter difference50055Joint load high50056Joint collision detected50057Joint not synchronized50058Tool coord. system error50059Erreur de référentiel50060Incorrect tool50061Erreur de référentiel50062Cercle imprécis50063Circle uncertain50065Kinematics error50066Robot not active50067Unit not active50076Orientation not correct50078Too many close positions50079Cannot use wrist weaving50080Position not compatible50082Path calculation time exceeded50083Speed lowered by system.50085Too many user frames.50086Singularity problem50087Singularity problem50088Restart not possible50089Weaving changed50091Restart not possible50092Axis computer response50093Load too large50094TuneServo not possible50095Cannot access joint.50096TuneServo not allowed50100Manipulator configuration50101Manipulator configuration50102Manipulator configuration50103Manipulator configuration50104Manipulator configuration50106Numerical param error50107Configuration error50124Zone converted to fine point50128Manipulator configuration50130Erreur de synchronisation50131Erreur d'étalonnage50132Commutation failed50133No signals available50134Avertissementconcernantlevecteurde correction50135SoftAct not possible.50136SoftAct not possible50137No finepoint50138Arm check point limit50139Arm check point limit50140Chargeutiletropelevee50141Jog or Speed error50142Manipulator configuration50143Robot axes configuration50144Displacement frame uncertain50145Kinematic limitation50146Restart limitation50147Power fail restart failed50151MOC\_MAILBOX1\_E RROR50152MOC\_MAILBOX2\_E RROR50153Command not allowed50154Command not allowed50155Power fail restart failed50156Not an Independent Joint50157Avertissementconcernantlevecteurde correction50158Sensor process missing50159No external process50160Cannot reach position50161Singularity area50162Internal position error50163Position adjustment50164Deactivation not possible50167Avertissement:Nouvelle synchronisation50168New sync on arg50170Manque process50171Speed too low50172MoveJ not allowed50173Fine point necessary50174WObj not connected50175Conveyor moving50176Conveyor not active50177Unable to restart50178Non optimal movement50180Avert. vecteur de correc.50181Out of coupled range50182Jog in wrong direction50183Robot outside work area50184Avertissementconcernantlevecteurde correction50185Avertissementconcernantlevecteurde correction50186Missing function50187Missing function50188Mouvement non optimal50189Relay signal not found50190Permanent interpolator lock error50191Too many TCP speed's50192Jogging error50193Joint not synchronized50194Internal position error50195Cannot move independent50196Calibration failed50197Calibration failed50198Calibration failed50199Erreur calibration50200Torque error50201Orientation outside reach50202' Dc-link ' mal configuré50203Measurement node used50204Motion supervision triggered50205Data logger error50206Avertissementverification50207Add intermediate point50208Missing function50209Kinematic limitation50210Load identification fail50211Manque option50212Missing option50213Err. rot. référentiel50214Work area configuration failed50215Load identification fail50216Erreur config MS50217Err. redémarrage MS50218Path not finished50219Communication M/S50220No input signal50221Object outside limit50222Mismatch type - MechUnit50223Décélération trop longue50224Cannot define load50225Anciennezonememoired'amorcage securise perdue50226Motor reference error50227Test signal error50228Test signal error50229Test signal error50230Test signal error50231Log signal unit not active50232Saturation Kv50233Saturation Ki50234Overflow during logging50235No Motion interrupts received50236Reference underrun50237Reference task error50238Erreur de calcul50239Optimal Em. Stop change50240Optimal Em. Stop change50241Missing function50242Unsync due to system parameters50243Aucunelimited'acceleration50244Absolute Accuracy calibration failed50245Commandenonautorisee50246Linked motor error50247Clear of Path failed50248Internal Servo Tool error50249Programmed force reduced50250Calibration force reduced50251Tool opening failed50252Tool opening failed50253Cannot deactivate unit50254Linked motor error.50255Missing function50256Sync pos warning50257Sync speed outside limits50258Sensor direction error50259Sensor max distance error50260Sensor Check dist error50261WZone outside work area50262WZone outside work area50263Duty factor is too high50264Saved parameters used50265Thickness out of reach50266Echecdelademandedefermeture50267Open request failed50268Calibration failed50269Tune value out of limit50270Pre position ignored50271Poor event accuracy50272Manipulator configuration50273Manipulator configuration50274Manipulator configuration50275Motion configuration50276Manipulator configuration50277Manipulator configuration50278Manipulator configuration50279Motion configuration50280System configuration50281Another process failed50282Record not ready50283Unknown record file name50284Cannot activate Mechanical Unit50285DitherAct not possible50286Mix of coordinated frames50287Unit not stopped in a controlled position50288Sync ID mismatch50289Point type mismatch at sync50290Service unavailable50291Deactivation not allowed50292Activation not allowed50293Configuration error50294Transmission error of data50295Motion data missing50296SMB memory / data mismatch50297Memory updated in SMB50298Memory updated in cabinet50299Avertissementconcernantlecontrolede la vitesse50300Robot memory not used50301All robot data missing50302Sensor data missing50303Controller data missing50304Transfer of data not allowed50305Old SMB board used50306Load identification error50307Extended working range50308In Position timeout50309Absolute Accuracy error50310Independent joint not active50311Cannot activate Mechanical Unit in task50312Unitemecaniquedejaactivedansune autre tache50313Independent move reset restarted50314Mouvementindependantinaccessible50315Corner path failure50316Absolute accuracy not activated50317Disconnecting the Drive Module not allowed50318Reconnecting the Drive Module not allowed50319Cannot activate Mechanical Unit50320Moduled'entrainementdeconnecte50321Moduled'entrainementreconnecte50322Mechanical Unit not connected to Motion task50323Failed to read force sensor50324Force control calibration failed50325Failed to activate force control50326Failed to deactivate force control50327Failed to start references50328Parameter error in FCRefSprForce or FCRefSprTorque50329Parameter error in FCRefSprForce50330Parameter error in FCRefSprTorque50331Parameter error in FCRefForce50332Parameter error in FCRefTorque50333Error FCRefLine, FCRefRot or FCRefCircle50334Parameter error in FCRefLine50335Parameter error in FCRefSpiral50336Erreur deparametre dans FCGetProcessData50337Force sensor not setup50338Parameter error in FCCondAdvanced50339Parameter error in FCCondTime50340Error in force control box definition50341Error in force control cylinder definition50342Error in force control sphere definition50343Error in force control cone definition50344Joints outside limits in force control50345Force control supervision error50346Motor temperature error50347Progam pointer moved in Force Control mode50348Log signal definition failed50349Same synchronization ID50350Software Equalizing Not Allowed50351Independent Move not allowed50352Number of move instruction mismatch50353Failed to read data from encoder card50354Ordered force reference is too large50355Ordered torque reference is too large50356Ordered MaxForce is too large50357Ordered MaxTorque is too large50358Close to singularity when in force control50359Path Recorder on StorePath level not allowed50361Brake release error50362Axis / brake motor fault50363SyncMoveOn failed50364Axis in current vector mode50365Cyclic Brake Check Warning50366Reference Error50367Sensor Sync machine stop50368Too Short distance between equidistant events50369Calibration using stored offset failed50370Transfer of data to robot memory failed50371The programmed speed is too high50372Contact force too high50373Too high Event Preset Time50374FC SpeedChange program stop error50375Dynamic load too high50376Geometric interpolation failed50377Only allowed in position control50378Error in FCSetMaxForceChangeTune50379Active mechanical units have changed50380Checksum error50381Speed too low50382Weave pattern error50383Cartesian Soft Servo configuration error50384Cartesian Soft Servo quaternions invalid50385Cartesian Soft Servo activation failed50386Cartesian Soft Servo offset activation failed50387Cartesian Soft Servo close to unstable50388Cartesian Soft Servo position supervision error50389Cartesian Soft Servo singularity50390Cartesian Soft Servo speed supervision50391Cartesian Soft Servo movement not allowed50392SafeMove communication error50393Force offset applied in non-soft direction50394The Path for the Unit is cleared50396Default FC force supervision error50397Path frame rotation speed error50398Circle begins with a frame change50399Absolute Accuracy circle is first movement instruction50400Motion configuration error50401Startup synchronization failed50402Correction is not ended in a finepoint50403AW board not connected50404Additional axis movement during Wrist Interpolation50405Coordinated movement during Wrist Interpolation50406Wrist Interpolation point not on circle plane50407Wrist axis locked50408Wrist joint limit50409Wrist Interpolation not possible50410Collinear targets in wrong order50411Maximum allowed programmed TCP load exceeded50412Error in speed change tuning instruction50413Bleeder resistor overload error50414Bleeder resistor overload50415Motor temperature error50416Motor temperature close to maximum50417Drive unit overload error50418Drive unit overload50419Common base\_frame error50420IndCnv Mechanical Unit Error50421IndCnv Tracking Single Error50422IndCnv and Independent joint error50423IndCnv Time before indexing move too50424Type de robot IndCnv non pris en charge50425Friction FFW parameter is not On50426Out of interpolation objects50427Joint not synchronized after calibration50428SC Software synchronization started50429CSS parameter damping obsolete50430Underrun in the axis computer50431Predicted Collision50432Identical Base Frames50433Position changed to inside working area50434Position changed to inside working area50435Inconsistent system parameter50436Robot configuration error50437Follower axis is connected to wrong Motion Planner50438Motor off sequence has timed out50439Soft servo activation failure50440Correction generator lost50441SMB battery (axis) fault50442Robot axis configuration error50443Lack of Internal Event Objects50444Motion supervision50445Sync on/off not allowed while External Motion Interface is active50446External Motion Interface ramp time increased50447Incorrect mechanical units for External Motion Interface50448Error in External Motion Interface input50449Mechanical unit close to joint bound50450External Motion Interface activation error50451External Motion Interface deactivation error50452External Motion Interface cyclic error50453Move not allowed in External Motion Interface50454External Motion Interface position supervision50455External Motion Interface speed supervision50456Close to singularity while External Motion Interface active50457External Motion Interface configuration failed50458Programmed speed too high50459External Motion Interface input out of bounds50460External Motion Interface deactivation not allowed50461Too many continuous log signals50462Cartesian speed too high50463Log server communication error50464A collision has occurred50465Tuning of robot stiffness parameters is recommended50466Measurement Channel Conflict50467Brake Relay Conflict50468Cartesian speed limits changed50469I/O controlled axis configuration failed50470I/O controlled axis not ready for activation50471I/O controlled axis not ready50472Absolute accuracy data missing50473Ascii Log configuration failed50474Target in a singularity50475Target in a singularity50476AxisCal error50477Axis Calibration data missing50478Could not deactivate lead-through50479Cannot jog joints in independent mode50480I/O controlled axis RefSync failed50481I/O controlled axis not synchronized50482Search speed not reached50483Movement in wrong direction50484Stop-point too far away from circle50486Load supervision50487Motion configuration50488Using old target definition50489Trigg distance larger than movement length50490Measurement error detected50491Dual-arm base frame error50492Error during jogging50493LockAxis4 not supported50494Revolution counters missing50495Axis Calibration error50496Conveyor Tracking position error at pick50497Maximum number of axes in drive module reached50498Motion configuration50499Exceeded maximum allowed path correction50500Functionality has Beta status50501Short movements50502Collision Avoidance load error50503Collision Avoidance inactive during jogging50504Moving in wrong direction50505Spot Gun configuration warning50506Spot Gun missing tip error50507Movement detected when brakes are applied50508Conveyor board connection lost50509License error50511Safety Controller violation prevented.50512Controller restarted50513Activation or deactivation not allowed50514No calibration tool found50515Too many attempts during calibration50516Speed too high during calibration50517Speed too low during calibration50518High speed detected after contact50519Incorrect contact force50520Incorrect contact force50521Calibration timed out50522Unexpected collision detected50523Calibration speed not reached